Fault
108 is a temperature sensor issue.
It may
be able to be cleared by doing following.
On the main menu (where you see the house)
- click the right
hand arrow to enter the menu
- Scroll down by
the down arrow to installation
- Press the right
arrow
- First line
shows 'Fault Code 108'
- Clear the fault
by clicking right hand arrow.
Return to main screen by pressing the arrow to the left
twice.
·
Ensure a temperature reading for roof cavity (and outside
if auto cooler is installed) is on the main screen. For earlier software
version you may have to press the left arrow located at the bottom of the
controller.
·
Next press left arrow once and you will see “HUM RH” at the
top of the screen. Ensure a relative humidity is displayed in the roof cavity
(& outside if auto cooler is installed).
If the temperature and/or relative humidity is not
displayed the applicable temperature sensor may have failed. If the software
version on the controller is before 2.43, the controller will need to be
replaced with the the current version (ie 2.45). You can find the software
version at the bottom of the installation page in the main menu
Please
note that the system might reboot to refresh.
If the
fault doesn't clear, please reply to you case email and update us including
software version located at bottom of installation screen in main menu.
We will
have to book in a customer service technician to come out and replace the
temperature sensor and or updated firmware is required (fees apply)